Project with NuSMV
Problem 1.
Follow the instructions and prepare yourself for using NuSMV.
➢ nuSMV 2.5.4 Download: http://nusmv.fbk.eu/NuSMV/download/getting-v2.html
➢ Tutorial:
http://nusmv.fbk.eu/NuSMV/tutorial/
➢ Install the binary
Run NuSMV from the command line (NOTICE the -int option):
./NuSMV -int
NuSMV > help
NuSMV > read_model -h
usage: read_model [-h] [-i <file>]
-h Prints the command usage.
-i <file> Reads the model from the specified <file>. NuSMV > quit
Problem 2.
Consider the following example.
MODULE main VAR
request : boolean;
state : {ready,busy}; ASSIGN
init(state) := ready; next(state) := case
state = ready & request : busy;
TRUE : {ready,busy}; esac;
SPEC
AG(request -> AF state = busy)
Copy the code above in a text file and call it short.smv. Then, call NuSMV and load this file:
NuSMV -int
NuSMV > read_model -i short.smv NuSMV > flatten_hierarchy NuSMV > encode_variables NuSMV > build_model
At this point NuSMV is ready to perform simulation and verification. You can verify the formula above with the command check_ctlspec. You can verify more CTL formulas with the command check_ctlspec -p “CTL-formula”. For instance, check whether or not the formula AG(request -> AX(state=busy)) is true.
1
Tasks:
- 1) Read the tutorial of Nusmv 2.5 and learn the syntax, draw the state diagram of above code.
- 2) Come up with 3 more CTL properties and check against the model.
Problem 3.
Consider the following 3-bit counter.
MODULE counter_cell(carry_in) VAR
value : boolean; ASSIGN
init(value) := FALSE;
next(value) := value xor carry_in; DEFINE
carry_out := value & carry_in; MODULE main
VAR
bit0 : counter_cell(TRUE);
bit1 : counter_cell(bit0.carry_out); bit2 : counter_cell(bit1.carry_out);
Without using NuSMV, try to uderstand what the code does (see tutorial).
Copy the code above in a text file and call it counter.smv. Then, call NuSMV and load this file:
./NuSMV -int
NuSMV > read_model -i counter.smv
NuSMV > flatten_hierarchy
NuSMV > encode_variables
NuSMV > build_model
At this point NuSMV is ready to perform simulation and verification.
Simulation:
At this point you verify that your understanding of the code was correct. To perform simulation, first you have to select a state from the set of initial states:
NuSMV > pick_state -i
(with this command you select a state interactively (-i). As there is only one initial state, you just have to confirm the only option available). The command simulates -i <number> is used to perform simulation. <number> specifies the number of steps you want to simulate,
e.g.,
NuSMV > simulate -i 1
The evolution of the system is deterministic. Try a few steps and check that your guess was correct.
Verification:
You can verify CTL formulas with the command check_spec -p “CTL-formula”. For instance, check whether or not the formula AX(bit0.value=0) is true.
Tasks:
2
- 1) Draw state diagram for this model
- 2) Come up with 3 more CTL property and check against above model.
Problem 4. Model checking VS Simulation
Consider the following microwave oven controller design written in Verilog.
// Microwave oven
module microwave(clk, sys_reset, reset, closeDoor, starOven, done, States);
input input reg output
clk, sys_reset;
reset, closeDoor, starOven, done; Start, Close, Heat, Error;
reg [3:0] States;
always @ (posedge clk) begin
if (sys_reset == 1’b1) begin
{Start, Close, Heat, Error} <= 4’b0000; end
else begin
case ({Start, Close, Heat, Error}) 4’b0000:
if (closeDoor) {Start, Close, Heat, Error} <= 4’b0100;
else if (starOven) {Start, Close, Heat, Error} <= 4’b1001; 4’b1001:
if (closeDoor) {Start, Close, Heat, Error} <= 4’b1101; 4’b1101:
if (~closeDoor){Start, Close, Heat, Error} <= 4’b1001;
else if (reset) {Start, Close, Heat, Error} <= 4’b0100; 4’b0100:
if (~closeDoor){Start, Close, Heat, Error} <= 4’b0000;
else if (starOven) {Start, Close, Heat, Error} <= 4’b1100; 4’b1100: {Start, Close, Heat, Error} <= 4’b1110; 4’b1110: {Start, Close, Heat, Error} <= 4’b0110; 4’b0110:
if (~closeDoor){Start, Close, Heat, Error} <= 4’b0000;
else if (done) default:
endcase end
end
always @ (*) begin
{Start, Close, Heat, Error} <= 4’b0100; {Start, Close, Heat, Error} <= 4’b0000;
States = {Start, Close, Heat, Error}; end
endmodule // microwave
Tasks:
1) Understand the design and draw the transition diagram for the design 3
- 2) Propose 5 new CTL properties. Describe them in English first, then in CTL forms. Your properties should be different from those proposed by other students.
- 3) Create Verilog test benches and run simulation to verify your properties, justify your test result. (show the test result in script form instead of wave form)
- 4) Model the design in NuSMV
- 5) Prove/disprove them by the NuSMV package.
- 6) Explain why the property is true or false and if the test result meets your expectation.
- 7) Compare the model checking to simulation, and discuss the advantages and disadvantages of
the above two verification methods.
Sample properties:
If an error condition occurs, it must be reset before the oven may heat. G((Close=0 * Start=1) -> (Error=0 R Heat=0));
The oven can’t be heated if the door is not closed. Heat=0 U Close=1;
4